{"id":217,"date":"2017-10-09T17:10:42","date_gmt":"2017-10-09T17:10:42","guid":{"rendered":"https:\/\/learn.hydrologystudio.com\/channel-studio\/?post_type=ht_kb&#038;p=217"},"modified":"2025-06-05T13:47:21","modified_gmt":"2025-06-05T13:47:21","slug":"setting-section-centerline","status":"publish","type":"ht_kb","link":"https:\/\/learn.hydrologystudio.com\/channel-studio\/knowledge-base\/setting-section-centerline\/","title":{"rendered":"Setting the Section Centerline"},"content":{"rendered":"\n<p>Depending on the station and elevation points entered, there may be times you&#8217;ll want to reset the centerline of your channel section. This centerline station is used by the Plan view and 3D view tabs to position the cross-section relative to the centerline of the river reach. In other words, the centerline station is the intersection of the cross-section line and the river reach.<\/p>\n\n\n\n<figure class=\"wp-block-image is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"675\" height=\"298\" src=\"https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/SectionCenterline.png\" alt=\"\" class=\"wp-image-218\" srcset=\"https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/SectionCenterline.png 675w, https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/SectionCenterline-300x132.png 300w, https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/SectionCenterline-50x22.png 50w, https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/SectionCenterline-60x26.png 60w, https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/SectionCenterline-100x44.png 100w\" sizes=\"auto, (max-width: 675px) 100vw, 675px\" \/><\/figure>\n\n\n\n<p>IMPORTANT: This feature has no affect on water surface profile calculations and is not available when using TIN Surfaces.<\/p>\n\n\n\n<p>When entering your section for the first time, or after editing your section&#8217;s station \/ elevation data, the program attempts to set the centerline station to the location of the channel section invert. However, if more than one elevation share this invert, it will be set to the first one as shown below.<\/p>\n\n\n\n<figure class=\"wp-block-image alignnone wp-image-219 size-full is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"1290\" height=\"772\" src=\"https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/SetCenterlineSta.png\" alt=\"\" class=\"wp-image-219\" srcset=\"https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/SetCenterlineSta.png 1290w, https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/SetCenterlineSta-300x180.png 300w, https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/SetCenterlineSta-768x460.png 768w, https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/SetCenterlineSta-1024x613.png 1024w, https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/SetCenterlineSta-50x30.png 50w, https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/SetCenterlineSta-60x36.png 60w, https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/SetCenterlineSta-100x60.png 100w\" sizes=\"auto, (max-width: 1290px) 100vw, 1290px\" \/><figcaption class=\"wp-element-caption\">Check CL (upper right) to On to view the centerline station. Drag the vertical section line to desired location.<\/figcaption><\/figure>\n\n\n\n<p>To reset, be sure the CL check box in the upper right is checked. Then drag the highlighted vertical section line to the new position. No need to click [Apply].<\/p>\n\n\n\n<figure class=\"wp-block-image is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"1156\" height=\"627\" src=\"https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/ResetCenterlineSta.png\" alt=\"\" class=\"wp-image-220\" srcset=\"https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/ResetCenterlineSta.png 1156w, https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/ResetCenterlineSta-300x163.png 300w, https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/ResetCenterlineSta-768x417.png 768w, https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/ResetCenterlineSta-1024x555.png 1024w, https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/ResetCenterlineSta-50x27.png 50w, https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/ResetCenterlineSta-60x33.png 60w, https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/ResetCenterlineSta-100x54.png 100w\" sizes=\"auto, (max-width: 1156px) 100vw, 1156px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Example Moving the Section Location on the Reach<\/h3>\n\n\n\n<figure class=\"wp-block-image is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"1161\" height=\"649\" src=\"https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/CenterLine.png\" alt=\"\" class=\"wp-image-1303\" srcset=\"https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/CenterLine.png 1161w, https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/CenterLine-300x168.png 300w, https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/CenterLine-768x429.png 768w, https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/CenterLine-1024x572.png 1024w, https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/CenterLine-50x28.png 50w, https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/CenterLine-60x34.png 60w, https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-content\/uploads\/sites\/5\/2017\/10\/CenterLine-100x56.png 100w\" sizes=\"auto, (max-width: 1161px) 100vw, 1161px\" \/><\/figure>\n\n\n\n<p>In the section above, the CL was set originally to the section&#8217;s midpoint, Station 105 ft (210\/2). The CL line was then dragged to the left to a new position at 60. In Plan view the entire cross-section will be shifted 45 feet to the right as looking upstream.<\/p>\n\n\n\n<p>Note that the CL option will be disabled when connected to a TIN surface. Disengage the TIN surface to use this feature.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Depending on the station and elevation points entered, there may be times you&#8217;ll want to reset the centerline of your channel section. This centerline station is used by the Plan view and 3D view tabs to position the cross-section relative to the centerline of the river reach. In other words,&#8230;<\/p>\n","protected":false},"author":1,"comment_status":"closed","ping_status":"closed","template":"","format":"standard","meta":{"footnotes":""},"ht-kb-category":[],"ht-kb-tag":[],"class_list":["post-217","ht_kb","type-ht_kb","status-publish","format-standard","hentry"],"_links":{"self":[{"href":"https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-json\/wp\/v2\/ht-kb\/217","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-json\/wp\/v2\/comments?post=217"}],"version-history":[{"count":7,"href":"https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-json\/wp\/v2\/ht-kb\/217\/revisions"}],"predecessor-version":[{"id":2004,"href":"https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-json\/wp\/v2\/ht-kb\/217\/revisions\/2004"}],"wp:attachment":[{"href":"https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-json\/wp\/v2\/media?parent=217"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-json\/wp\/v2\/ht-kb-category?post=217"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/learn.hydrologystudio.com\/channel-studio\/wp-json\/wp\/v2\/ht-kb-tag?post=217"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}